<±×¸²1>Àº SEC Standard UPS ÄÁÆ®·Ñ·¯ÀÇ Àб⼳Á¤ ¿¹ Àε¥ DEVICE ¼³Á¤Àº Åë½ÅÆ÷Æ®(COM1), Åë½Å¼Óµµ(19200), Æи®Æ¼ºñÆ®(0), µ¥ÀÌÅͺñÆ®(8), ½ºÅéºñÆ®(1), ¼øÀ¸·Î ÀÔ·ÂÇÑ´Ù.(Ethernet »ç¿ë ½Ã ¿¬°á¹æ¹ý(TCP/IP), IP ¹øÁö(192.168.1.70), ¼ºñ½º Æ÷Æ® ¹øÈ£(6001) ¼øÀ¸·Î ÀÔ·Â)
¶ÇÇÑ ¿É¼Ç ºÎ¿¡´Â Åë½Å ÇÁ·ÎÅäÄÝÀÇ CRC »ç¿ë¿©ºÎ(0 = »ç¿ë¾ÈÇÔ, 1 = »ç¿ë, ±âº» : 0)¸¦ 0 ¶Ç´Â 1·Î ÀÔ·ÂÇÑ´Ù.
´Ü CRC »ç¿ë( 1 )À¸·Î ¼³Á¤ÇßÀ» °æ¿ì Åë½Å Àü¿¡ AP0 ¸í·ÉÀ» ¸ÕÀú Àü¼ÛÇÑ´Ù.
<±×¸² 1> SEC Standard UPS ÀÇ Åë½ÅÆÄÀÏÀÛ¼º ¿¹
SEC Standard UPS ÀÇ Àбâ´Â ´ÙÀ½°ú °°ÀÌ ¼³Á¤ÇÏ¿© »ç¿ëÇÑ´Ù.
READ | ½ºÅ×ÀÌ¼Ç (»ç¿ë¾ÈÇÔ) |
Àбâ¸í·É | ÀÐÀ»ÁÖ¼Ò (»ç¿ë¾ÈÇÔ) |
¸Þ¸ð¸®ÀúÀåÀ§Ä¡ | ÀдÂ
°³¼ö (°¢ ¸í·Éº° °íÁ¤) |
FLOAT, | 0, | ST1, | 0, | 0, | 1, |
FLOAT, | 0, | ST2, | 0, | 10, | 1, |
FLOAT, | 0, | ST3, | 0, | 30, | 1, |
FLOAT, | 0, | ST4, | 0, | 50, | 1, |
FLOAT, | 0, | ST5, | 0, | 70, | 1, |
1) ½ºÅ×ÀÌ¼Ç : »ç¿ë¾ÈÇÔ.
2) Àбâ¸í·É: AP1, AP2, ATR, MAN, MOD, NOM, SDA, ST1 ~ ST5, STR, UID, VER Áß¿¡¼ ¼±ÅÃ.
3) ÀÐÀ» ÁÖ¼Ò : »ç¿ë¾ÈÇÔ.
4) ¸Þ¸ð¸® ÀúÀå À§Ä¡ : Àоî¿Â »óÅ°ªÀ» ÀúÀåÇÒ ¹öÆÛÀ§Ä¡.
5) Àд ũ±â: Çѹø¿¡ Àоî¿Ã Ç׸ñ°¹¼ö. °¢ Àб⠸í·Éº°·Î °íÁ¤ (Ç¥1 ~ Ç¥16 ÂüÁ¶).
Àüü Àд ũ±â | ³»¿ë | ³»¿ë |
ÃÖ´ë 46 | Available parameter 1 | Available ÆĶó¸ÞÅÍ ¹øÈ£ 1 ~ 46 |
<Ç¥ 1> AP1 Àбâ¸í·ÉÀÇ ÀдÂÅ©±â ¹× µ¥ÀÌÅÍ ³»¿ë.
Àüü Àд ũ±â | ³»¿ë | ³»¿ë |
ÃÖ´ë 43 | Available parameter 2 | Available ÆĶó¸ÞÅÍ ¹øÈ£ 47 ~ 89 |
<Ç¥ 2> AP2 Àбâ¸í·ÉÀÇ ÀдÂÅ©±â ¹× µ¥ÀÌÅÍ ³»¿ë.
Àüü Àд ũ±â | ³»¿ë | ÃÖ´ë µ¥ÀÌÅÍ ±æÀÌ | ´ÜÀ§ |
1 | Auto Reboot | 1 | Á¤¼ö1 =
ON(auto), 2 – OFF(manual) |
<Ç¥ 3> ATR Àбâ¸í·ÉÀÇ ÀдÂÅ©±â ¹× µ¥ÀÌÅÍ ³»¿ë.
Àüü Àд ũ±â | ³»¿ë | ÃÖ´ë µ¥ÀÌÅÍ ±æÀÌ | ´ÜÀ§ | ºñ°í |
1 | Manufacturer | 32 | ¹®ÀÚ | ¹®ÀÚ¿ À̹ǷΠÅë½Å ¸Þ¸ð¸®·Î Àü¼Û¾ÈµÊ |
<Ç¥ 4> MAN Àбâ¸í·ÉÀÇ ÀдÂÅ©±â ¹× µ¥ÀÌÅÍ ³»¿ë.
Àüü Àд ũ±â | ³»¿ë | ÃÖ´ë µ¥ÀÌÅÍ ±æÀÌ | ´ÜÀ§ | ºñ°í |
1 | Model | 64 | ¹®ÀÚ | ¹®ÀÚ¿ À̹ǷΠÅë½Å ¸Þ¸ð¸®·Î Àü¼Û¾ÈµÊ |
<Ç¥ 5> MOD Àбâ¸í·ÉÀÇ ÀдÂÅ©±â ¹× µ¥ÀÌÅÍ ³»¿ë.
Àüü Àд ũ±â |
³»¿ë | ÃÖ´ë µ¥ÀÌÅÍ ±æÀÌ | ´ÜÀ§ | ºñ°í |
12 | Nominal ÀÔ·Â Àü¾Ð | 3 | º¼Æ® | V |
Nominal ÀÔ·Â ÁÖÆļö | 3 | HZ | 0.1 HZ |
|
Nominal Ãâ·Â Àü¾Ð | 3 | º¼Æ® | V |
|
Nominal Ãâ·Â ÁÖÆļö | 3 | HZ | 0.1 HZ |
|
Nominal VA Rating | 5 | VA | Volts-amps |
|
Nominal Ãâ·Â Àü·Â | 5 | W |
|
|
Low Battery Time | 2 | ºÐ | Minutes |
|
Audiable Alarm | 1 | 1 : disabled 2 : enabled 3 : muted 4 : disabled until low battery |
||
Low Voltage Transfer Point | 3 | º¼Æ® | V |
|
High Voltage Transfer Point | 3 | º¼Æ® | V |
|
Battery Installed Date | 8 | ¿ù/ÀÏ/³â |
||
Nominal
|
5 | ÀÏ | days |
<Ç¥ 6> NOM Àбâ¸í·ÉÀÇ ÀдÂÅ©±â ¹× µ¥ÀÌÅÍ ³»¿ë.
Àüü Àд ũ±â | ³»¿ë | ÃÖ´ë µ¥ÀÌÅÍ ±æÀÌ | ´ÜÀ§ |
1 | Shutdown type | 1 | Á¤¼ö 1 = UPS output, 2 = UPS system |
<Ç¥ 7> SDA Àбâ¸í·ÉÀÇ ÀдÂÅ©±â ¹× µ¥ÀÌÅÍ ³»¿ë.
Àüü Àд ũ±â | ³»¿ë | ÃÖ´ë µ¥ÀÌÅÍ ±æÀÌ | ´ÜÀ§ | ºñ°í |
8 |
|
1 | 0 : Good 1 : Weak 2 : Replace |
|
|
1 | 0 : Ok 1 : Low 2 : Depleted |
||
|
1 | 0 : Floating 1 : Charging 2 : Resting 3 : Discharging |
||
Seconds on
|
5 | ÃÊ | Seconds |
|
Estimated Minutes | 3 | ºÐ | Minutes |
|
Estimated Charge | 3 | % | Percent |
|
|
4 | V | 0.1 V |
|
|
4 | A | 0.1 A |
<Ç¥ 8> ST1 Àбâ¸í·ÉÀÇ ÀдÂÅ©±â ¹× µ¥ÀÌÅÍ ³»¿ë.
Àüü Àд ũ±â | ³»¿ë |
ÃÖ´ë µ¥ÀÌÅÍ ±æÀÌ | ´ÜÀ§ | ºñ°í |
14 | ÀÔ·Â Line Bads |
3 | Á¤¼ö |
|
ÀÔ·Â Num Lines |
1 | Á¤¼ö (1 ~ 3) |
||
ÀÔ·Â ÁÖÆļö 1 |
3 | HZ | 0.1 HZ |
|
ÀÔ·Â Àü¾Ð 1 |
4 | V | 0.1 V |
|
ÀÔ·Â Àü·ù 1 |
4 | A | 0.1 A |
|
ÀÔ·Â Àü·Â 1 |
5 | W |
|
|
ÀÔ·Â ÁÖÆļö 2 |
3 | HZ | 0.1 HZ |
|
ÀÔ·Â Àü¾Ð 2 |
4 | V | 0.1 V |
|
ÀÔ·Â Àü·ù 2 |
4 | A | 0.1 A |
|
ÀÔ·Â Àü·Â 2 |
5 | W |
|
|
ÀÔ·Â ÁÖÆļö 3 |
3 | HZ | 0.1 HZ |
|
ÀÔ·Â Àü¾Ð 3 |
4 | V | 0.1 V |
|
ÀÔ·Â Àü·ù 3 |
4 | A | 0.1 A |
|
ÀÔ·Â Àü·Â 3 |
5 | W |
|
<Ç¥ 9> ST2 Àбâ¸í·ÉÀÇ ÀдÂÅ©±â ¹× µ¥ÀÌÅÍ ³»¿ë.
Àüü Àд ũ±â |
³»¿ë |
ÃÖ´ë µ¥ÀÌÅÍ ±æÀÌ | ´ÜÀ§ | ºñ°í |
14 |
Ãâ·Â ÁÖÆļö |
3 | HZ | 0.1 HZ |
Ãâ·Â Num Lines |
1 | Á¤¼ö (1 ~ 3) |
||
Ãâ·Â Àü¾Ð 1 |
4 | V | 0.1 V |
|
Ãâ·Â Àü·ù 1 |
4 | A | 0.1 A |
|
Ãâ·Â Àü·Â 1 |
5 | W |
|
|
Ãâ·Â Load 1 |
3 | % | Percent |
|
Ãâ·Â Àü¾Ð 2 |
4 | V | 0.1 V |
|
Ãâ·Â Àü·ù 2 |
4 | A | 0.1 A |
|
Ãâ·Â Àü·Â 2 |
5 | W |
|
|
Ãâ·Â Load 2 |
3 | % | Percent |
|
Ãâ·Â Àü¾Ð 3 |
4 | V | 0.1 V |
|
Ãâ·Â Àü·ù 3 |
4 | A | 0.1 A |
|
Ãâ·Â Àü·Â 3 |
5 | W |
|
|
Ãâ·Â Load 3 |
3 | % | Percent |
<Ç¥ 10> ST3 Àбâ¸í·ÉÀÇ ÀдÂÅ©±â ¹× µ¥ÀÌÅÍ ³»¿ë.
Àüü Àд ũ±â |
³»¿ë |
ÃÖ´ë µ¥ÀÌÅÍ ±æÀÌ | ´ÜÀ§ | ºñ°í |
11 |
Bypass ÁÖÆļö |
3 | HZ | 0.1 HZ |
Bypass Num Lines |
1 | Á¤¼ö (1 ~ 3) |
||
Bypass Àü¾Ð 1 |
4 | V | 0.1 V |
|
Bypass Àü·ù 1 |
4 | A | 0.1 A |
|
Bypass Àü·Â 1 |
5 | W |
|
|
Bypass Àü¾Ð 2 |
4 | V | 0.1 V |
|
Bypass Àü·ù 2 |
4 | A | 0.1 A |
|
Bypass Àü·Â 2 |
5 | W |
|
|
Bypass Àü¾Ð 3 |
4 | V | 0.1 V |
|
Bypass Àü·ù 3 |
4 | A | 0.1 A |
|
Bypass Àü·Â 3 |
5 | W |
|
<Ç¥ 11> ST4 Àбâ¸í·ÉÀÇ ÀдÂÅ©±â ¹× µ¥ÀÌÅÍ ³»¿ë.
Àüü Àд ũ±â | ³»¿ë | ÃÖ´ë µ¥ÀÌÅÍ ±æÀÌ | ºñ°í |
15 | ¿Âµµ °æº¸ | 1 | 0 : No Alarm1 : Alarm |
ÀÔ·Â Bad °æº¸ | 1 | ||
Ãâ·Â Bad °æº¸ | 1 | ||
Overload °æº¸ | 1 | ||
Bypass Bad °æº¸ | 1 | ||
Ãâ·Â Off °æº¸ | 1 | ||
UPS Shutdown °æº¸ | 1 | ||
Charger Failure °æº¸ | 1 | ||
½Ã½ºÅÛ Off °æº¸ | 1 | ||
Fan Failure °æº¸ | 1 | ||
Fuse Failure °æº¸ | 1 | ||
General Failure °æº¸ | 1 | ||
Awaiting Power °æº¸ | 1 | ||
Shutdown Pending °æº¸ | 1 | ||
Shutdown Imminent °æº¸ | 1 |
<Ç¥ 12> ST5 Àбâ¸í·ÉÀÇ ÀдÂÅ©±â ¹× µ¥ÀÌÅÍ ³»¿ë.
Àüü Àд ũ±â | ³»¿ë | ÃÖ´ë µ¥ÀÌÅÍ ±æÀÌ | ºñ°í |
2 | Test Result Summary | 1 | 0 : No Test 1 : Test Passed 2 : Test in Progress 3 : General Test Failed 4 :
5 : Deep Test Failed |
Test Result Detail | 64 | ¹®ÀÚ¿ À̹ǷΠÅë½Å ¸Þ¸ð¸®·Î Àü¼Û¾ÈµÊ |
<Ç¥ 13> STR Àбâ¸í·ÉÀÇ ÀдÂÅ©±â ¹× µ¥ÀÌÅÍ ³»¿ë.
Àüü Àд ũ±â | ³»¿ë | ÃÖ´ë µ¥ÀÌÅÍ ±æÀÌ | ºñ°í |
1 | UPS Baud Rate | 5 | 1200, 2400, 4800, 9600, 19200 |
<Ç¥ 14> UBR Àбâ¸í·ÉÀÇ ÀдÂÅ©±â ¹× µ¥ÀÌÅÍ ³»¿ë.
Àüü Àд ũ±â | ³»¿ë | ÃÖ´ë µ¥ÀÌÅÍ ±æÀÌ | ´ÜÀ§ | ºñ°í |
1 | UPS Indentification | 64 | ¹®ÀÚ | ¹®ÀÚ¿ À̹ǷΠÅë½Å ¸Þ¸ð¸®·Î Àü¼Û¾ÈµÊ |
<Ç¥ 15> UID Àбâ¸í·ÉÀÇ ÀдÂÅ©±â ¹× µ¥ÀÌÅÍ ³»¿ë.
Àüü Àд ũ±â | ³»¿ë | ÃÖ´ë µ¥ÀÌÅÍ ±æÀÌ | ´ÜÀ§ | ºñ°í |
1 | Software Version | 32 | ¹®ÀÚ | ¹®ÀÚ¿ À̹ǷΠÅë½Å ¸Þ¸ð¸®·Î Àü¼Û¾ÈµÊ |
<Ç¥ 16> VER Àбâ¸í·ÉÀÇ ÀдÂÅ©±â ¹× µ¥ÀÌÅÍ ³»¿ë.
µðÁöÅÐ Ãâ·Â ¼³Á¤¹ý
µðÁöÅÐ Ãâ·ÂÀº SEC Standard UPS ÀÇ »óÅ°ªÀ» ¹Ù²Ù´Â ±â´ÉÀ¸·Î ´ÙÀ½°ú °°ÀÌ »ç¿ëÇÑ´Ù.
µðÁöÅÐ Ãâ·Â TAG ¼³Á¤ ½Ã ÇÊ¿äÇÑ 5 °¡Áö
PORT ¿¬°áµÈ PORT ¹øÈ£ 0 ~ 255
STATION »ç¿ë¾ÈÇÔ
ADDRESS »ç¿ë¾ÈÇÔ
EXTRA1 ¼¼Æøí·É ATR (Auto Reboot : Ç¥ 3 ÂüÁ¶),
NOM(Ç¥ 5 ÂüÁ¶ – ÀÛ¾÷ µð·ºÅ丮ÀÇ SCAN ¼¹ö µð·ºÅ丮¿¡ NOM_DATA.??? (??? = port no)¿¡
Ç¥5 ¿Í °°Àº ¼ø¼·Î Ãâ·Â µ¥ÀÌÅÍ ÀÛ¼º),
PSD(Shutdown action : -1 – abort, 0 – immediate, 1 >= - seconds until shutdown),
RWD(Shutdown type : seconds), SDA(Ç¥ 7 ÂüÁ¶),
STD(Startup after delay : -1 – abort, 0 – immediate, 1 >= - seconds until startup),
TST(Test : -1 – Abort Test, 0 – No Effect, 1 – General Test, 2 – Battery Test, 3 – Deep Test),
UBR(UPS Baud Rate : 1200, 2400, 4800, 9600, 19200),
UID(Sets UPS ID String : ÃÖ´ë 64 ¹®ÀÚ, ÀÛ¾÷ µð·ºÅ丮ÀÇ SCAN ¼¹ö µð·ºÅ丮¿¡
UID_DATA.??? (??? = port no)¿¡ UPS ID ¸¦ ÀÛ¼º),
CN1 (Á¤·ù±â ON/OFF : 1 = ON, 0 = OFF),
CN2 (ÀιöÅÍ ON/OFF : 1 = ON, 0 = OFF),
CN3 (½ºÅ×ƽ ON/OFF : 1 = ON, 0 = OFF),
AP0 (CRC üũ»ç¿ë ¸í·É : 1 = AP0 ¸í·É ½Ã CRC °¡ Æ÷ÇÔµÊ, 0 = AP0 ¸í·É ½Ã CRC ¾øÀ½),
EXTRA2 »ç¿ë¾ÈÇÔ
¿¹ 1) Port : 0, Extra1 : ATR À¸·Î ¼³Á¤ÇÏ°í µðÁöÅÐ Ãâ·ÂÀ» Çϸé SEC Standard UPS ÀÇ Auto Reboot »óÅ°ªÀ» ¹Ù²Ü(ON/OFF) ¼ö ÀÖ´Ù.
¾Æ³¯·Î±× Ãâ·Â ¼³Á¤¹ý
¾Æ³¯·Î±× Ãâ·Â¼³Á¤Àº µðÁöÅÐ Ãâ·Â ¼³Á¤°ú µ¿ÀÏÇÏ°í Ãâ·Â °ª¸¸ ÁöÁ¤ÇÑ °ªÀ¸·Î Ãâ·ÂÇÑ´Ù.
<±×¸² 2>´Â SEC UPS ÀåºñÀÇ ¾ÕÂÊ ¸ð½ÀÀÌ´Ù.
<±×¸² 2> SEC UPS ÀåºñÀÇ ¾ÕÂÊ ¸ð½ÀÀÇ ¿¹